Home Electrical Assessment Prices
Price
$200.00 Please allow for 1-3 hours
for a complete and thorough job.
Home Electrical Assessment will consist of checking all electrical connections in the house and Garage to insure safety for your family. I will check all connections outlets to: Refrigerator, Electric/Gas Stove, Trash Compactor, Microwave, Dishwasher, Garbage Disposal, Washing Machine, Dryer, Boiler Furnace, Gas Furnace, Central Air Conditioning, Water Heater, Water Softener, Sump Pump and Central Vacuum.
I will check every electrical outlet, electrical switch, ceiling lights/ceiling fans for function and looseness. I will record if any GFCI 's are needed.
Before we go further, here are a few serious safety concerns to consider about the outlets in your home. All are National Electrical Code (NEC) Requirements for Receptacles :
GFCI
AFCI
Weather Resistant Receptacles
Tamper-Resistant (TR) Receptacles
WHAT IS A GFCI? A ground fault circuit interrupter, called a GFCI or GFI, is an inexpensive electrical device that can either be installed in your electrical system or built into a power cord to protect you from severe electrical shocks. Needs to be in your kitchen and bathrooms.
Arc-Fault Circuit Interrupter (AFCI)
is a circuit breaker that breaks the circuit when it detects the electric arcs that are a signature of loose connections in home wiring. Loose connections, which can develop over time, can sometimes become hot enough to ignite house fires.
Where are Weather Resistant Receptacles required?
According to the NEC, all 15-amp and 20-amp, 125-volt and 250-volt non-locking receptacles installed in wet or damp locations shall be weather resistant receptacles. This means they should be installed in any area exposed to weather: Residential decks, porches, yards etc. Residential and commercial pool areas. Outdoor electrical outlets differ from indoor outlets because they have watertight covers that protect the outlet even with a cord plugged in. Plus, the National Electrical Code requires all outdoor outlets to be GFCI outlets (ground fault circuit interrupter outlets).
Tamper-Resistant (TR) Receptacles
These receptacles have spring-loaded shutters that close off the contact openings, or slots, of the receptacles. When a plug is inserted into the receptacle, both springs are compressed and the shutters then open, allowing for the metal prongs to make contact to create an electrical circuit. Because both springs must be compressed at the same time, the shutters do not open when a child attempts to insert an object into only one contact opening, and there is no contact with electricity. Tamper- resistant receptacles are an important next step to making the home a safer place for children.
Why require tamper-resistant electrical receptacles?
Each year, approximately 2,400 children suffer severe shock and burns when they stick items into the slots of electrical receptacles. It is estimated that there are six to 12 child fatalities a year related to this.
If homeowners do not have children, are TR receptacles required?
Yes. Owners or tenants of homes and apartments change frequently. In addition, exposure to electrical shock and burn accidents are not limited to a child’s own home. Children visit homes of relatives and friends who don't have children of their own. This requirement ensures all new homes and apartments are safe for children, whether the home is their own or they are there on a temporary basis.
The overall objection is safety in checking all electrical connections. Here is the Home Electrical Assessment Checklist:
Electrical Outlets will be checked for:
Check if outlet works
Check that outlet is grounded
Check for GFCI near sink
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Electrical switches will be checked for:
Check to see if light switch is safe
Check if switch works with light
Check for loose cover plate
Check if switch receptacle is loose
Ceiling Fan/Light
Check for function
Check for looseness
Check for balance/mounts
Refrigerator
Check for proper electrical connection
Check outlet for loose connections
Other
Electric Stove
Check electrical fan connection
Check for proper electrical connection
Check outlet for loose connections
Other
Trash Compactor
Check for proper electrical connection
Check outlet for loose connections
Other
Microwave
Check for proper electrical connection
Check outlet for loose connections
Other
Dishwasher
Check if it has GFCI outlet
Check hardwired/outlet electrical connections
Other
Garbage Disposal
Check for proper electrical connection
Check if it has GFCI for outlet and switch
Other
Bathroom Vanity
Check if it has GFCI for outlet and switch
Other
All Electrical outlets
Check if outlet works
Check that outlet is grounded
Check for GFCI near sink
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other
All Electrical Switch
Check if switch works with light
Check for loose cover plate
Check if switch receptacle is loose
Check if recommend replacement
Other
Ceiling Fan/Light
Check for function
Check for looseness
Check for balance/mounts
Other
Basement Ceiling Exposed joist
Check all exposed electrical wires
Check for correctly secured
Check junction boxes
Check all outlets
Check ceiling lights
Other
Breaker Panel
Visual inspection of electrical box
Check for signs of water
Check every circuit breaker for function
Check all breaker wires for being loose
Record Loose Breaker wires
Other
Kitchen Island Electrical Outlets
Check if outlet works
Check that outlet is grounded
Check for GFCI near sink
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other
Kitchen Island Electrical Switches
Check if switch works
Check for loose cover plate
Check if switch receptacle is loose
Check if recommend replacement
Other
Washing Machine
Check all switches/outlets
Check that outlet is grounded
Check for GFCI
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other
Dryer
Check all switches/outlets
Check all electrical connections
Other
Boiler Furnace
Check all electrical connections
Check that outlet is grounded
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other
Gas Furnace
Check that outlet is grounded
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other
Central Air Conditioning
Check all switches/outlets
Check that outlet is grounded
Check for GFCI
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other
Water Heater
Check all switches/outlets
Check that outlet is grounded
Check for GFCI
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other
Water Softener
Check all switches/outlets
Check that outlet is grounded
Check for GFCI
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other
Sump Pump
Check all switches/outlets
Check that outlet is grounded
Check for GFCI
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other
Basement Washer Basin
Check all switches/outlets
Check that outlet is grounded
Check for GFCI near basin
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other
Attic
Check all electrical connections
Check function of all switches/outlets
Check that outlet is grounded
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other
Central Vacuum
Check all switches/outlets
Check that outlet is grounded
Check for GFCI
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other
T.V. Wall Mounts/Shelves
Check VCR/DVR/Cable/Sound bar connections
Check for electrical overload
Check all switches/outlets
Check that outlet is grounded
Check for loose cover plate
Check if outlet receptacle is loose
Check if recommend replacement
Other